Description

Interactive Forza FX1500LCD /840W, 8 out, giga & coax, tower-120VBusiness

MPN: Forza FX-1500LCD

Capacity: 1500VA/840W

Topology: 

Interactive

Waveform: 

Simulated sine wave

Voltage: 

120V

Type of input: 

NEMA 5-15P

Type of output: 

8 x NEMA 5-15R

Communication: 

USB

Visual indicator: 

LCD status screen

Management software: 

Forza Tracker
FX-2200LCD_DK_Banner2_ENG.png

BATTERY SELF-TEST

Keeping your UPS healthy year-roundDesigned to reveal any weakness in order to prevent major failures

FX_Product_Master-Icono1.png

AUTOMATIC VOLTAGE REGULATION

Complete AVR protection against voltage irregularitiesEssential in areas where voltage fluctuations occur frequently, providing clean and stable power

FX_Product_Master-Icono2.png
FX-2200LCD_DK_Banner3_ENG.png

COMMUNICATION PORT

Enhanced communication and control capabilities Enables the automatic shutdown function, safely powering down connected computers

FX_Product_Master-Icono3.png

DATA LINE PROTECTION

Forza FX1500LCD

Protection for data signals across phone and network linesPrevents stray charges from damaging your communication equipment

FX_Product_Master-Icono4.png
FX-2200LCD_DK_Banner4_ENG.png

THERMOFUSE PROTECTION

Increased reliability and peace of mindPower disconnection function when transformer temperatures become too high

FX_Product_Master-Icono5.png

COLD START FUNCTION

Ultimate power reserve for less downtimeInstantly start the UPS in battery mode without AC utility power

FX_Product_Master-Icono6.png

NTERACTIVE UPS 1500VA/840W, 8 OUT, GIGA & COAX, TOWER-120V | BUSINESS

Forza FX1500LCD
 Interactive topology

Interactive UPS offer a cost effective solution with low energy consumption ratings, extending the overall life cycle of batteries.

Voltage regulation is accomplished without switching to battery mode.
 Battery backup

Supplies battery-derived backup power during blackouts, preventing loss of critical information and minimizing equipment stress caused by a hard shutdown.

Delivers reserved energy long enough for equipment to properly shut down.
 Automatic voltage regulation (AVR)

Provides clean and stable AC power by automatically increasing low voltages during brownouts and decreasing overvoltages without tapping into the reserved battery power when irregularities are present on the main utility line.

 Automatic shut-off


Guard your equipment against potentially damaging power fluctuations and other irregularities in the electrical supply by shutting down the power when voltage levels become too low or too high.

 Surge protection, overload protection, electric discharge and voltage protection
Diverts excess voltage away from connected equipment during power surges or power spikes without reducing battery power used to run primary critical equipment.
Extends battery life by preventing system overloads and controlling charging currents.
Resettable circuit breaker
Automatically prevents the flow of electricity in an electric circuit as a safety measure upon detecting undesirable high voltage levels.
Can be reset to resume operation.
 MOV Technology
Metal Oxide Varistor (MOV) technology helps absorb and it redirects transient energy preventing stray electricity from reaching protected equipment.
 Thermofuse protection
Instantly disconnects the power when internal temperatures become dangerously high.
 Power filters
Reduces electromagnetic interference (EMI) and radio frequency interference (RFI) to block unwanted noise, providing clean and distortion-free electricity to all power outlets.
 Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
 Battery self-test
Ensures early failure notifications of bad or old batteries for immediate replacement, preventing any unexpected and unforeseen backup power issues.
 Audible alarm
Provides audible notification of changing utility power and UPS power conditions for when the UPS is installed in hard to reach places or not easily seen by the user.
 Flame retardant material
All of our products are constructed with fire retardant ABS material, guaranteeing that if any failures are present, the equipment will not go up in flames.
 Cold start function
Reserves temporary battery power used to start up the UPS in battery mode when the utility power is out.
Restores immediate emergency power to the load after installing new batteries.
Data line protection
Built-in data line protection prevents power surges that travel through telephone or Ethernet lines from causing damage to sensitive electronics.
 Status LCD
Displays live status of the UPS with detailed information on battery and power conditions, alerting users to potential problems before they can affect equipment and cause costly downtime.
 Communication ports
USB port enables the automatic shutdown function, safely powering down connected computers so as to prevent important data loss.
Remotely manage and monitor UPS operations with the included user-friendly dashboard interface.
 Forza tracker management software

Allows control and monitoring of multiple UPS units through a network connection.

The software also prevents data loss from power outages by safely shutting down the UPS units while allowing the immediate detection and correction of any operation issues with minimal or no delay.

 Coaxial protection

Helps protect sensitive and mission critical surveillance equipment from damage due to potential overvoltage and electrostatic discharges on coaxial transmission lines.

 Ventilation system

Rear mounted extraction fan helps remove excess heat from the inside housing, guaranteeing to keep components within acceptable operating temperatures.

You may also like to check out: APC BACK UPS PRO BR 1500VA MPN: BR1500M2-LM